首页 >报价 >商务服务 > 认证服务>防水连接器UL认证,UL2238认证,UL认证公司

防水连接器UL认证,UL2238认证,UL认证公司

数量(件) 面议
1
  • 供货总量: 电议
  • 最小起订: 1件
  • 发货地址: 广东深圳市
  • 付款方式: 面议
  • 发布日期:2021-10-28
  • 访问量:60
咨询电话:139-1314-2465
打电话时请告知是在机电之家网上看到获取更多优惠。谢谢!
7

优尔检测(广东)有限公司

实名认证 企业认证
  • 企业地址:

更多>>推荐产品

详细参数
品牌 UL 规格型号 UL1977
编号 齐全 计量单位 1件
付款方式 面议 参考价格 0
价格单位 人民币 供货量 不限
说明书,报价手册及驱动 暂无相关下载 其他资料下载 暂无相关下载
产地 深圳 发货地 广东深圳市

产品详情

Connectors for Use in Data, Signal, Control and Power Applications - Component

The devices covered under this category are incomplete in certain constructional features or restricted in perbance capabilities and are intended for use as components of complete equipment bted for investigation rather than for direct separate installation in the field. THE FINAL ACCEPTANCE OF THE COMPONENT IS DEPENDENT UPON ITS INSTALLATION AND USE IN COMPLETE EQUIPMENT SUBMITTED TO UL.

GENERAL
This category covers single- and multi-pole connectors intended for factory assembly to copper conductors or printed wiring boards for use in data, signal, control and power applications within and between electrical equipment. These connectors may employ crimp terminals, solder terminals, quick-connect terminals, insulation displacement or insulation-piercing terminals, pressure terminal connectors, wire-binding screws, or other terminals that are intended for factory wiring.

PRODUCT MARKINGS AND RATINGS
Reusability — These devices have not been investigated for reusability.

Current Interruption — Unless otherwise noted in the individual Recognitions, these devices have not been investigated for current interruption (making or breaking a mated connection under load), nor for connection to branch-circuit receptacle outlets. A device intended exclusively for disconnecting use is marked "Not for Current Interrupting" or "For Disconnecting Use Only," or with an equivalent statement.

Electrical Rating — The devices covered under this category are generally marked with assigned ratings up to 1000 A and up to 600 V ac or dc. Devices with assigned electrical ratings have been investigated for their current-carrying capability under conditions representing the manufacturer's intended use with operating temperatures not exceeding the connector's insulating material or terminated conductors. (Also see Condition of Acceptability #1 below for devices without an assigned current rating.)

Flammability — Devices marked with a flammability class have demonstrated compliance with the applicable flame class as described in ANSI/UL 94, "Tests for Flammability of Plastic Materials for Parts in Devices and Appliances." Type 0 devices (rated less than 8.3 A and less than 30 V rms [42 V peak]) have not been investigated for a Flammability rating. Small components with an overall volume of less than 2500 mm3 (0.15 in.3) may be classed as SC-0, SC-1 or SC-2 as described in ANSI/UL 1694, "Tests for Flammability of Small Polymeric Component Materials."

Direct-contact Applications — Devices that have insulating materials that have been buated for CTI, HAI, HWI, Mechanical RTI, and other properties commonly applied in end-product investigations will include this inbation under "Conditions of Acceptability" in the individual connector Report. Acceptance for use in a product where such properties are required by the end-use product standard (such as applications where the material is in direct contact with live parts) are determined during the end-product investigation.

Maximum Operating Temperature — The insulating materials used in devices have been investigated for a maximum operating temperature (MOT). The MOT may be assigned up to the Electrical RTI of the polymeric material.

Mating Connectors — Connectors of Types 1A, 1B, 2, 3, 4 or 5 are intended for use with a mating connector from the same manufacturer. Intermixing of connectors from different manufacturers is permitted when a suitable investigation is conducted and this provision is noted as a Condition of Acceptability in the Report available from the manufacturer.

Contacts and Housing — Contacts and housings may be packaged and sold separaby. Compliance has been investigated on the same manufacturer's complete assembly of the contacts and housings, with the investigated combination detailed in the manufacturer's Report. Intermixing of contacts and housings from different manufacturers is permitted when a suitable investigation is conducted and this provision is noted as a Condition of Acceptability in the Report available from the manufacturer.

CONDITIONS OF ACCEPTABILITY
Consideration is to be given to the following Conditions of Acceptability when these components are employed in the end-use equipment:

1. Devices without a current rating have not been investigated for current-carrying capability and shall be investigated in the end-use product.
2. The suitability of the mounting means shall be determined in the end-use product.
3. Unless otherwise noted in the individual Recognitions, these devices have not been investigated for use in equipment grounding applications.
4. The maximum operating temperature for any connector shall not exceed the rated operating temperature as noted in the individual Recognitions.
Additional Conditions of Acceptability may be included in the Report available from the manufacturer.

REQUIREMENTS
The basic standard used to investigate products in this category is UL 1977, "Component Connectors for Use in Data, Signal, Control and Power Applications."





1 Scope



1.1 These requirements cover single and multipole connectors, intended for factory assembly to copper or    copper alloy conductors or    printed wiring boards, for use in data, signal, control and power applications within and between electrical equipment.



1.2 These requirements apply to devices categorized as follows (See Figure 1.1):



a)    Type 0 rated less than 8.3 A and less than 30 V rms (42 V peak);



b)    Type 1A rated less than 8.3 A and from 30 V up to and including 600 V ac or    dc, or    both;



c)    Type 1B rated from 8.3 A up to and including 200 A, and less than 30 V rms (42 V peak);



d)    Type 2 rated from 8.3 A to less than 31 A and from 30 V up to and including 600 V ac or    dc or    both;



e)    Type 3 rated from 31 A up to and including 200 A and from 30 V up to and including 600 V ac or    dc, or    both.



f)    Type 4 rated from greater than 200 A up to and including 1000 A, and up to and including 600 V ac or    dc.



g)    Type 5 rated less than 31 A and from 601 V up to and including 6000 V ac or    dc, or    both.



Type designations used in this Standard only serve as a guide to determine appropriate requirements, and do not represent an assigned rating. A device without an assigned current rating is considered to be either a Type 0 or    Type 1A depending upon the assigned voltage rating.



1.2 Figure 1.1Connector type designations



1.3 This standard does not directly apply to the following devices, but may be used to supplement the requirements within these standards when a device is buated to these standards:



a)    Devices produced integrally with flexible cord or    cable that are covered by the Standard for Cord Sets and Power-Supply Cords, UL 817;



b)    Devices intended for connection to the branch circuit, such as attachment plugs, cord connectors, receptacles, inlets, and outlets, that are covered by the Standard for Attachment Plugs and Receptacles, UL 498;



c)    Devices solely intended for direct connection to the branch circuit in accordance with the National Electrical Code, NFPA 70, and that are provided with contacts of the pin and sleeve type, that are covered by the Standard for Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type, UL 1682;



d)    Devices consisting of wiring terminals and supporting blocks intended for the connection of wiring that are covered by the Standard for Terminal Blocks, UL 1059;



e)    Devices intended for use with becommunications networks, that are covered by the Standard for Inbation Technology Equipment – Safety – Part 1: General Requirements, UL 60950-1, or    the Standard for Communications Circuit Accessories, UL 1863;



f)    Devices such as wire connectors and soldering lugs that are covered by the Standards for Wire Connectors, UL 486A-486B; Splicing Wire Connectors, UL 486C; or    Equipment Wiring Terminals for Use with Aluminum and/or    Copper Conductors, UL 486E;



g)    Devices such as quick-connect terminals that are covered by the Standard for Electrical Quick-Connect Terminals, UL 310.



1.4 The requirements in this standard may not entirely address all possible situations due to the wide variety of products and designs. In those situations, the Standard for Attachment Plugs and Receptacles, UL 498 may be used to supplement the requirements in this standard. Where a conflict exists between the requirements of UL 498 and UL 1977, the requirements of UL 1977 shall take precedence.



优尔检测电线电缆全球燃烧测试中心,仅燃烧测试实验室用地就达到1100多平方,投资约1500多万,
电线电缆燃烧测试中心检测范围:
(1)网线/光缆/功率线/火灾报线/天线:美国UL/加拿大CSA标准: CM/CMR/CMP/FT4/FT6级大型燃烧;
(2)欧洲建筑法规强制指令CPR EN50399标准成束热释放量燃烧,B,C,D,E等级全项测试;
(3)国标GB18380线缆成束燃烧 A, B, C,D级成束燃烧;
(4)英国耐火线缆BS6387和BS8491,GB/T 19666(N,NJ,NS);
(5)美国VW-1/IEC60332-1-2/EN60332-1-2单根垂直燃烧;
(6)橡塑材料UL94/国标GB/T 8815阻燃测试; 
( 7)氧指数、卤酸气体、灼热丝、漏电起痕、PH值等测试

产品体系认证: 

UL、CCC、CSA、CE、ETL、TUV、VDE、PSE、KTL、GS、FDA、FCC、e-Mark、SASO、GOST、DOT等全球认证服务 ; 

ISO9001、ISO14000、SA8000、TS16949、OHSA18000等国际质量体系认证; 

安规环保检测: 安全、环保、环境、燃烧、EMC、RF、RoHS、REACH等项目检测; 

安规技能培训: 产品安全测试、实验室操作人员培训、安规工程师培训、专业技能培训等 

详询Sunny 139-1314-2465

温馨提示

  • 还没找到想要的产品吗? 立即发布采购信息,让供应商主动与您联系!

免责声明:所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责,机电之家网对此不承担任何责任。机电之家网不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由您自行协商解决。
友情提醒:本网站仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的平台。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请采购商谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择!如您遇到欺诈等不诚信行为,请您立即与机电之家网联系,如查证属实,机电之家网会对该企业商铺做注销处理,但机电之家网不对您因此造成的损失承担责任!
您也可以进入“消费者防骗指南”了解投诉及处理流程,我们将竭诚为您服务,感谢您对机电之家网的关注与支持!

在线询盘/留言 请仔细填写准确及时的联系到你

  • 您的姓名:*
  • 联系手机:*
  • 固话电话:
  • 联系邮箱:
  • 所在单位:
  • 需求数量:*
  • 咨询内容:
  • 您要求厂家给您提供:
    规格型号 付款条件 产品目录 最低订货量
    运送资料 提供样本 库存情况 包装材料

您是不是在找