西门子模块6ES7288-1ST20-0AA1|授权模块代理商

西门子模块6ES7288-1ST20-0AA1|授权模块代理商


The SINAMICS S120 Cabinet Modules‑2 system comprises Active Line Connection Modules and Motor Modules in chassis‑2 bat.

Active Line Connection Modules‑2

Active Line Connection Modules‑2 comprise a Line Connection Module, an Active Interface Module, and an Active Line Module installed in a cabinet system.

Active Line Connection Modules‑2 can supply energy to the intermediate DC circuit and return regenerative energy to the line supply (energy recovery).

Active Line Connection Modules‑2 generate a regulated DC voltage which remains constant despite fluctuations in the line voltage. However, in this case, the line voltage must remain within the permissible tolerance range. Active Line Connection Modules‑2 draw a virtually sinusoidal current from the supply system. Almost no harmonics occur. The total harmonic distortion factors of the current THD(I) and voltage THD(U) are typically in the range of approx. 3 % for rated current. THD(I) is calculated according to IEEE 519 (2014) and THD(U) according to IEC 61000-2-4 (2002). The bent limit values of IEEE 519 (2014) are typically complied with.

Active Line Connection Modules‑2 always also contain a Clean Power Filter and the required pre-charging b circuit for the Active Line Module.

Active Line Connection Module-2 with Active Interface Module and Active Line Module ≤800 A

Active Line Connection Module-2 with Active Interface Module and Active Line Module >800 A

Motor Modules

Each SINAMICS S120 Cabinet Module‑2 is equipped with a Motor Module in chassis‑2 bat and covers the power range from 315 kW to 800 kW (380 V to 480 V). The power rating can be extended up to approx. 4560 kW by connecting up to six Motor Modules in parallel.

技术规范

General technical specifications

Electrical specifications

Line voltages

380 ... 480 V 3 AC, ±10 % (-15 % <1 min)

Line system configurations

Grounded TN/TT systems or non-grounded IT systems

Line frequency

47 ... 63 Hz

Output frequency 1)

 

  • Control mode Servo

0 ... 550 Hz

  • Control mode Vector

0 ... 550 Hz

  • Control mode V/f

0 ... 550 Hz

Efficiency

 

  • Motor Module

> 98.5 %

Overvoltage category

III acc. to EN 61800‑5‑1

Control b

Vector/Servo control with and without encoder or V/f control

Fixed speeds

15 fixed speeds plus 1 minimum speed, beterizable (in the default setting, 3 fixed setpoints plus 1 minimum speed are selectable using terminal strip/PROFIBUS/PROFINET)

Skippable speed ranges

4, beterizable

Setpoint resolution

0.001 rpm digital (14 bits + sign)
12 bits analog

Braking operation

With Active Line Connection Modules, four-quadrant operation as standard (energy recovery).
Braking by means of a Motor Module.

Cabinet system

Cabinet system

Rittal TS 8, doors with double-bit key, three-section base plates for cable entry

Paint finish

RAL 7035 (indoor requirements)

Mechanical specifications

Degree of protection

IP20 (higher degrees of protection up to IP54 optionally available)

Protection class

I acc. to EN 61800‑5‑1

Touch protection

EN 50274/DGUV regulation 3 when used as intended

Cooling b

Forced air cooling AF according to EN 60146

Ambient conditions

Storage 2)

Transport 2)

Operation

Ambient temperature

-25 ... +55 °C (-13 ... 131 °F)

-25 ... +70 °C (-13 ... +158 °F)
from -40 °C (-40 °F) for 24 hours

0 ... +40 °C (32 ... 104 °F)
to +50 °C (122 °F) see derating data

Relative humidity

(condensation not permissible)

5 ... 95 %
Class 1K4 acc. to IEC 60721‑3‑1 (1997)

5 ... 95 % at 40 °C (104 °F)
Class 2K3 acc. to IEC 60721‑3‑2 (1997)

5 ... 95 %
Class 3K3 acc. to IEC 60721‑3‑3 (2002)

Environmental class/harmful chemical substances

Class 1C2
acc. to EN 60721‑3‑1 (1997)

Class 2C2
acc. to EN 60721‑3‑2 (1997)

Class 3C2
acc. to EN 60721‑3‑3 (2002)

Organic/biological influences

Class 1B1
acc. to EN 60721‑3‑1 (1997)

Class 2B1
acc. to EN 60721‑3‑2 (1997)

Class 3B1
acc. to EN 60721‑3‑3 (2002)

Mechanically active substances

Class 1S1
acc. to EN 60721‑3‑1 (1997)

Class 2S1
acc. to EN 60721‑3‑2 (1997)

Class 3S1
acc. to EN 60721‑3‑3 (2002)

Degree of pollution

2 acc. to IEC/EN 61800‑5‑1

Installation altitude

≤2000 m (6562 ft) above sea level without derating, >2000 m (6562 ft) see Characteristic curves/derating data

Mechanical strength

Storage 2)

Transport 2)

Operation

Vibratory load

Class 1M2
acc. to EN 60721‑3‑1 (1997)

Class 2M2
acc. to EN 60721‑3‑2 (1997)

  • Deflection

1.5 mm (0.06 in) at 5 ... 9 Hz

3.1 (0.12 in) mm at 5 ... 9 Hz

0.075 mm (0.003 in) at 10 ... 58 Hz

  • Acceleration

5 m/s² (16.4 ft/s²) at >9 ... 200 Hz

10 m/s² (32.8 ft/s²) at >9 ... 200 Hz

9.8 m/s² (32.2 ft/s²) at >58 ... 200 Hz

Shock load

Class 1M2
acc. to EN 60721‑3‑1 (1997)

Class 2M2
acc. to EN 60721‑3‑2 (1997)

Class 3M4
acc. to EN 60721‑3‑3 (2002)

  • Acceleration

40 m/s² (131 ft/s²) at 22 ms

100 m/s² (328 ft/s²) at 11 ms

100 m/s² (328 ft/s²) at 11 ms

Compliance with standards

Conbances/certificates of suitability, according to

CE (EMC Directive 2014/30/EU, Low voltage Directive 2014/35/EU, and Machinery Directive 2006/42/EC for Functional safety)

RCM

Radio interference suppression

SINAMICS converter systems are not designed for connection to the public grid (first environment). Radio interference suppression is compliant with the EMC product standard for variable-speed drives EN 61800‑3, "second environment" (industrial line supplies). EMC disturbances can occur when connected to the public grid. However, if additional measures are taken (e.g. → line filter), it can also be operated in the "first environment".



1) Higher output frequencies available on request.

2) In transport packaging.

Deviations from the specified class are underlined.

特性曲线

Derating data

SINAMICS S120 Cabinet Modules‑2 and the associated system components are rated for an ambient temperature of 40 °C and installation altitudes up to 1000 m above sea level.

At ambient temperatures > 40 °C, the output current must be reduced. Ambient temperatures above 50 °C are not permissible.

At installation altitudes > 1000 m above sea level, it must be taken into account that the air pressure, and therefore air density, decreases as the height increases. As a consequence, the cooling efficiency and the insulation capacity of the air also decrease.

Due to the reduced cooling efficiency, it is necessary to both reduce the ambient temperature and lower heat loss in the Cabinet Module by reducing the output current, whereby ambient temperatures lower than 40 °C may be offset to compensate.

The following table specifies the permissible output currents as a function of the installation altitude and ambient temperature for the various degrees of protection. (The permissible compensation between installation altitude and the ambient temperatures < 40 °C – air intake temperature at the entry to the Cabinet Module – has been taken into account in the specified values.)

The values apply under the precondition that it is guaranteed that the cooling air, as specified in the technical data, flows through the units as a result of the cabinet arrangement.

As an additional measure for installation altitudes from 2000 m up to 5000 m, an isolating transber is required in order to reduce transient overvoltages according to EN 60664‑1.
For additional inbation, please refer to the SINAMICS Low Voltage Engineering Manual.

Current derating factors for Cabinet Modules‑2 as a function of the ambient/air intake temperature, the installation altitude and the degree of protection

Degree of protection

Installation altitude above sea level

Current derating factor (as a percentage of the rated current)
for an ambient/air intake temperature of

 

m (ft)

15 °C (59 °F)

20 °C (68 °F)

25 °C (77 °F)

30 °C (86 °F)

35 °C (95 °F)

40 °C (104 °F)

45 °C (113 °F)

50 °C (122 °F)

IP20, IP21, IP23, IP43

0 ... 1000 (0 ... 3281)

100 %

100 %

100 %

100 %

100 %

100 %

83 %

69 %

1001 ... 1500 (3284 ... 4921)

100 %

100 %

100 %

100 %

100 %

98 %

81 %

67 %

1501 ... 2000 (4925 ... 6562)

100 %

100 %

100 %

100 %

100 %

93 %

78 %

65 %

2001 ... 2500 (6565 ... 8202)

100 %

100 %

100 %

100 %

96 %

 

 

 

2501 ... 3000 (8205 ... 9843)

100 %

100 %

100 %

99 %

 

 

 

 

3001 ... 3500 (9846 ... 11483)

100 %

100 %

100 %

 

 

 

 

 

3501 ... 4000 (11486 ... 13123)

100 %

100 %

96 %

 

 

 

 

 

4001 ... 4500 (13127 ... 14764)

100 %

97 %

 

 

 

 

 

 

4501 ... 5000 (14767 ... 16404)

98 %

 

 

 

 

 

 

 



Degree of protection

Installation altitude above sea level

Current derating factor (as a percentage of the rated current)
for an ambient/air intake temperature of

 

m (ft)

10 °C (50 °F)

15 °C (59 °F)

20 °C (68 °F)

25 °C (77 °F)

30 °C (86 °F)

35 °C (95 °F)

40 °C (104 °F)

45 °C (113 °F)

50 °C (122 °F)

IP54

0 ... 1000 (0 ... 3281)

100 %

100 %

100 %

100 %

100 %

100 %

83 %

69 %

54 %

1001 ... 1500 (3284 ... 4921)

100 %

100 %

100 %

100 %

100 %

98 %

81 %

67 %

52 %

1501 ... 2000 (4925 ... 6562)

100 %

100 %

100 %

100 %

100 %

93 %

78 %

65 %

50 %

2001 ... 2500 (6565 ... 8202)

100 %

100 %

100 %

100 %

96 %

 

 

 

 

2501 ... 3000 (8205 ... 9843)

100 %

100 %

100 %

99 %

 

 

 

 

 

3001 ... 3500 (9846 ... 11483)

100 %

100 %

100 %

 

 

 

 

 

 

3501 ... 4000 (11486 ... 13123)

100 %

100 %

96 %

 

 

 

 

 

 

4001 ... 4500 (13127 ... 14764)

100 %

97 %

 

 

 

 

 

 

 

4501 ... 5000 (14767 ... 16404)

98 %

 

 

 

 

 

 

 

 



Current derating for SINAMICS S120 Motor Modules in chassis‑2 bat as a function of the pulse frequency

To reduce motor noise or to increase output frequency, the pulse frequency can be increased relative to the factory setting (2.5 kHz). When the pulse frequency is increased, the derating factor of the output current must be taken into account. This derating factor must be applied to the currents specified in the technical specifications.
For additional inbation, please refer to the SINAMICS Low Voltage Engineering Manual.

Derating factor of the output current as a function of the pulse frequency

Motor Modules in chassis‑2 bat

Type rating
at 400 V

Output current
at 2.5 kHz

Derating factor

at pulse frequency

6SL3721-...

kW

A

4 kHz

5 kHz

7.5 kHz

8 kHz

380 ... 480 V 3 AC

1TE36-6BE0

315

655

78 %

67 %

48 %

45 %

1TE37-4BE0

355

740

78 %

67 %

48 %

45 %

1TE38-1BE0

400

810

78 %

67 %

48 %

45 %

1TE38-8BE0

450

910

78 %

67 %

48 %

45 %

1TE41-0BE0

500

975

78 %

67 %

48 %

45 %

1TE41-1BE0

560

1075

78 %

67 %

48 %

45 %

1TE41-2BE0

630

1200

78 %

67 %

48 %

45 %

1TE41-3BE0

710

1325

78 %

67 %

48 %

45 %

1TE41-5BE0

800

1495

78 %

67 %

48 %

45 %



Maximum output frequencies achieved by increasing the pulse frequency

The adjustable pulse frequencies – and therefore the output frequencies that can be achieved with the factory-set current controller clock cycles – are listed below.

Current controller clock cycle
TI

Adjustable pulse frequency
fp

Max. achievable output frequency fA

V/f mode

Vector mode

Servo mode

400 μs

2.5 kHz

208 Hz

208 Hz

5.0 kHz

416 Hz

300 Hz

7.5 kHz

550 Hz 1)

300 Hz



1) Higher frequencies on request. For more inbation, see https://support.industry.siemens.com/cs/document/104020669

Overload capability

SINAMICS S120 Cabinet Modules‑2 have an overload reserve, e.g. to handle breakaway torques. If larger surge loads occur, this must be taken into account in the configuration. For drives with overload requirements, the appropriate base-load current must therefore be used as a basis for the required load.

Permissible overload assumes that the converter is operated at its base-load current before and after the overload occurs, based on a duty cycle duration of 300 s (low overload, high overload) or 60 s (duty cycle S6).

Another precondition is that the Motor Modules are operated at their factory-set pulse frequency at output frequencies >10 Hz.

For temporary, periodic duty cycles with high variations of load within the duty cycle, the relevant sections of the SINAMICS Low Voltage Engineering Manual must be observed.

Motor Modules in chassis‑2 bat

Motor Modules with power units in chassis‑2 bat can be configured on the basis of different base-load currents.

The base-load current for low overload IL is based on a duty cycle of 110 % for 60 s.

Low overload

The base-load current for a high overload IH is based on a duty cycle of 150 % for 60 s.

High overload

The base-load current IS6 is based on a duty cycle of 200 % for 6 s.

Duty cycle S6 with initial load with a duty cycle duration of 60 s

Active Line Connection Modules‑2

The base-load current IL is based on a load cycle of 115 % for 60 s with a duty cycle duration of 300 s.

Low overload

The duty cycle with maximum current Imax_DC is based on a duty cycle of 150 % for 5 s with a duty cycle duration of 300 s.