ULTRAMAT 23 是一种创新型多组分分析仪,可利用 NDIR 原理测量最多三种对红外线敏感的气体。紫外分光光度计可用来测量浓度很低的 SO2 和 NO2。
通过使用电化学氧传感器或按照顺磁测量原理(“哑铃型”)工作的测量槽,也可以测量氧气 (O2)。使用附加的电化学 H2S 测量槽时,可以在沼气应用中进行测量。
使用 ULTRAMAT 23 气体分析仪,最多可连续测量 4 种气体组分。该装置可配有以下传感器:
- 适用于红外活性气体的红外检测器
- 适用于紫外活性气体的紫外光度计
- H2S 传感器(电化学)
- O2 传感器(电化学)
- O2 传感器(顺磁)
- 使用用于沼气厂的 ULTRAMAT 23 型气体分析仪,最多可以连续测量四种气体组分:两种红外敏感气体(CO2 和 CH4),以及采用电化学测量单元测量 O2 和 H2S。
- 使用配有顺磁性氧测量池的 ULTRAMAT 23 气体分析仪,可以连续测量最多 4 种气体组分:可测量三种红外敏感气体以及采用“哑铃型”测量单元测量 O2 。
- 使用配有紫外光度计的 ULTRAMAT 23 气体分析仪,可通过电化学传感器测量一种红外敏感气体、紫外活性气体(SO2、NO2)以及 O2。
优势
-
AUTOCAL with ambient air (depending on the measured component)
- Highly cost-effective as calibration gases are not required
- High selectivity thanks to multi-layer detectors, e.g. low cross-sensitivity to water vapor
-
Analyzer cells can be cleaned on site as required
- Cost savings due to reuse after contamination
-
Menu-assisted operation in plain text
- No manual required for operation, high level of operator safety
-
Service inbation and logbook
- Preventive maintenance; help for service and maintenance personnel; cost savings
-
Coded b levels protect against unauthorized access
- Increased safety
-
Open interface architecture (RS 485, RS 232, PROFIBUS, SIPROM GA)
- Simplified process integration; remote operation and control
Special benefits when used in biogas plants
- Continuous measurement of all four key components, including H2S
- Long service life of the H2S sensor even at increased concentrations; no diluting or backflushing necessary
- Introduction and measurement of flammable gases as occurring in biogas plants (e.g. 70% CH4) is permissible (German Technical Inspectorate/TÜV certificate)
应用
- Optimization of small firing systems
- Monitoring of exhaust gas concentration from firing systems with all types of fuel (oil, gas and coal) as well as operational measurements with thermal incineration plants
- Room air monitoring
- Monitoring of air in fruit stores, greenhouses, fermenting cellars and warehouses
- Monitoring of process control functions
- Atmosphere monitoring during heat treatment of steel
- For use in non-hazardous areas
Application areas in biogas plants
- Monitoring of fermenters for generating biogas (b and pure sides)
- Monitoring of gas-driven motors (power generation)
- Monitoring of feeding of biogas into the commercial gas network
Application area of bagnetic oxygen sensor
- Flue gas analysis
- Inerting plants
- Room air monitoring
- Medical engineering
Further applications
- Environmental protection
- Chemical plants
- Cement industry
Special versions
Separate gas paths
The ULTRAMAT 23 with 2 IR components without pump is also available with two separate gas paths. This allows the measurement of two measuring points as used e.g. for the NOx measurement before and after the NOx converter.
The ULTRAMAT 23 gas analyzer can be used in emission measuring devices and for process and safety monitoring.
Versions conbing to EN 14181 and EN 15267
According to EN 14181, which is standardized in the EU and required in many European countries, a QAL1 qualification test, i.e. certification of the complete measuring device including gas paths and conditioning, is required for continuous emission monitoring systems (CEMS). In accordance with EN 15267, this must be perbed by an independent accredited authority. In Germany, for example, the test is perbed by the German Technical Inspectorate (TÜV) and the test report is bted to the Federal/State Workgroup for Emission Control (Bund/Länder-Arbeitsgemeinschaft für Immissionsschutz - LAI) for examination/approval. Notification is then issued by the German Federal Environment Agency (Umweltbundesamt - UBA) in the Federal Gazette (Bundesanzeiger) as well as by the German Technical Inspectorate (TÜV) here: https://www.qal1.de/en.
In the UK, the QAL1 test reports are prepared by Sira Environmental of the Environmental Agency in accordance with the MCERTS scheme and bted for approval and publication on the SIRA Environmental websites. The other European countries rely either on the German or English certification scheme.
For use in EN 14181 applications, the devices with the article numbers 7MB235X in the Set CEM CERT (7MB1957) have undergone qualification testing according to German standards of EN 15267. These German Technical Inspectorate (TÜV) versions of the ULTRAMAT are suitable for measurement of CO, NO, SO2 and O2 according to sections 13 and 27 of the BlmSchV (Federal Emission Law of Germany) and TA Luft. Smallest measuring range tested and approved by the German Technical Inspectorate:
1 and 2-component analyzer
- CO: 0 to 150 mg/m3
- NO: 0 to 150 mg/m3
- SO2: 0 to 400 mg/m3
3-component analyzer
- CO: 0 to 250 mg/m3
- NO: 0 to 250 mg/m3
- SO2: 0 to 400 mg/m3
Also tested as additional measuring ranges in accordance with EN 15267-3:
- CO: 0 to 1 250 mg/m3
- NO: 0 to 2 000 mg/m3
- SO2: 0 to 7 000 mg/m3
Determination of the analyzer drift according to EN 14181 (QAL3) can be carried out manually or also with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission buation computers offer the possibility to read the drift data via the analyzer's serial interface and automatically record and process it in the buation computer.
Version with faster response time
The connection between the two condensation traps is equipped with a stopper to lead the complete flow through the measuring cell (otherwise only 1/3 of the flow), i.e. the response time is 2/3 faster. The functions of all other components remain unchanged.
Chopper purge
Consumption 100 ml/min (upstream pressure setting: approx. 3 000 hPa).
设计
-
19" rack unit with 4 U for installation
- In hinged frame
- In cabinets
-
Flow indicator for sample gas on front plate;
option: integrated sample gas pump (standard for bench-top version) - Gas connections for sample gas inlet and outlet as well as zero gas; pipe diameter 6 mm or ¼"
- Gas and electrical connections at the rear of the device (portable version: sample gas inlet at front)
Display and operator panel
- Operation based on NAMUR recommendation
- Simple, fast beterization and commissioning of analyzer
- Large, backlit LCD for measured values
- Menu-driven operator functions for beterization, test functions and calibration
- Washable membrane keyboard
- User help in plain text
- 6-language operating software
Inputs/outputs
- Three digital bs for sample gas pump On/Off, triggering of AUTOCAL and synchronization of several devices
- Eight relay outputs can be freely configured for fault, maintenance demanded, maintenance switch, limits, measuring range identification and external solenoid valves
- Eight additional digital bs and relay outputs as an option
- Electrically isolated analog outputs
Communication
RS 485 present in basic unit (connection from the rear).
Options
- RS 485/RS 232 converter
- RS 485/Ethernet converter
- RS 485/USB converter
- Incorporation in networks via PROFIBUS DP/PA interface
- SIPROM GA software as service and maintenance tool
ULTRAMAT 23, membrane keyboard and graphic display
ULTRAMAT 23, design
|
Designs – parts wetted by sample gas |
|||
|---|---|---|---|
|
Gas path |
19" rack unit |
Desktop unit |
|
|
With hoses |
Condensation trap/gas inlet |
- |
PA (polyamide) |
|
Condensation trap |
- |
PE (polyethylene) |
|
|
Gas connections 6 mm |
PA (polyamide) |
PA (polyamide) |
|
|
Gas connections ¼" |
Stainless steel, mat. no. 1.4571 |
Stainless steel, mat. no. 1.4571 |
|
|
Hose |
FPM (Viton) |
FPM (Viton) |
|
|
Pressure switch |
FPM (Viton) + PA6-3-T (Trogamide) |
FPM (Viton) + PA6-3-T (Trogamide) |
|
|
Flowmeter |
PDM/Duran glass/X10CrNiTi1810 |
PDM/Duran glass/X10CrNiTi1810 |
|
|
Angle units/T-pieces |
PA6 |
PA6 |
|
|
Internal pump, option |
PVDF/PTFE/EPDM/FPM/Trolene/stainless steel, mat. no. 1.4571 |
PVDF/PTFE/EPDM/FPM/Trolene/stainless steel, mat. no. 1.4571 |
|
|
Solenoid valve |
FPM70/Ultramide/stainless steel, mat. no. 1.4310/1.4305 |
FPM70/Ultramide/stainless steel, mat. no. 1.4310/1.4305 |
|
|
Safety condensation trap |
PA66/NBR/PA6 |
PA66/NBR/PA6 |
|
|
Analyzer chamber |
|||
|
Aluminum |
Aluminum |
|
|
Aluminum |
Aluminum, black anodized |
|
|
Stainless steel, black anodized, mat. no. 1.4571 |
Stainless steel, mat. no. 1.4571 |
|
|
CaF2, quartz |
CaF2 |
|
|
E353 |
E353 |
|
|
FPM (Viton) |
FPM (Viton) |
|
|
With pipes, only available in version "without pump" |
Gas connections 6 mm/¼" |
Stainless steel, mat. no. 1.4571 |
- |
|
Pipes |
Stainless steel, mat. no. 1.4571 |
- |
|
|
Analyzer chamber |
- |
||
|
Aluminum |
- |
|
|
Aluminum |
- |
|
|
Stainless steel, mat. no. 1.4571 |
- |
|
|
CaF2 |
- |
|
|
E353 |
- |
|
|
FPM (Viton) |
- |
|
Gas path
ULTRAMAT 23, portable, in sheet-steel housing with internal sample gas pump, condensation trap with safety filter on front plate, optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump; optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure without internal sample gas pump; optional oxygen measurement
ULTRAMAT 23, 19" rack unit housing without internal sample gas pump, with separate gas path for the 2nd measured component or for the 2nd and 3rd measured component, optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure, sample gas path version in pipes, separate gas path, always without sample gas pump, without safety filter and without safety condensation trap
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump and H2S sensor
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump and bagnetic oxygen measurement
ULTRAMAT 23, 19" rack unit enclosure with IR detector, UV photometer (UV module); optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure with UV photometer (UV module); optional oxygen measurement