首页 >产品 >电工电气 > 工控系统及装备> PLC>西门子模块代理商|巢湖西门子模块代理商

西门子模块代理商|巢湖西门子模块代理商

数量(件) 价格
300 700.00元/件
  • 最小起订: 1件
  • 发货地址: 上海 松江区
  • 发布日期:2022-10-09
  • 访问量:201
咨询电话:150-2129-2620
打电话时请告知是在机电之家网上看到获取更多优惠。谢谢!
5
  • 企业地址:上海市松江区广富林路4855弄52号3楼
添加微信好友

扫一扫,添加微信好友

详细参数
品牌西门子型号6ES7360-3AA01-0AA0
结构形式模块式安装方式现场安装
LD指令处理器其他加工定制

产品详情

西门子模块代理商|巢湖西门子模块代理商

西门子模块代理商|巢湖西门子模块代理商


Legend for the gas path figures

1

Inlet for sample gas/calibration gas

11

Sample gas pump

2

Gas outlet

12

Pressure switch

3

Inlet for AUTOCAL/zero gas or
inlet for sample gas/calibration gas (channel 2)

13

Flow indicator

14

Analyzer unit

4

Gas outlet (channel 2)

15

Safety condensation trap

5

Enclosure purging

16

Oxygen sensor (electrochemical)

6

Inlet of atmospheric pressure sensor

17

Atmospheric pressure sensor

7

Inlet/chopper purge

18

Hydrogen sulfide sensor

8

Condensation trap with filter

19

Oxygen measuring cell (bagnetic)

9

Safety fine filter

20

UV photometer (UV module)

10

Solenoid valve

   


操作模式

The ULTRAMAT 23 uses multiple independent measuring principles which work selectively.

Infrared measurement

The measuring principle of the ULTRAMAT 23 is based on the molecule-specific absorption of bands of infrared radiation, which in turn is based on the "single-beam procedure". A radiation source (7) operating at 600 °C emits infrared radiation, which is then modulated by a chopper (5) at 8 1/3 Hz.

The IR radiation passes through the sample chamber (4), into which sample gas is flowing, and its intensity is weakened as a function of the concentration of the measured component.

The detector chamber - set up as a two- or three-layer detector chamber - is filled with the component to be measured.

The first detector layer (11) primarily absorbs energy from the central sections of the sample gas IR bands. Energy from the peripheral sections of the bands is absorbed by the second (2) and third (12) detector layers.

The microflow sensor generates a pneumatic connection between the upper layer and the lower layers. Negative feedback from the upper and lower layers leads to an overall narrowing of the spectral sensitivity band. The volume of the third layer and, therefore, the absorption of the bands, can be varied using a "slide switch" (10), thereby increasing the selectivity of each individual measurement.

The rotating chopper (5) generates a pulsating flow in the detector chamber that the microflow sensor (3) converts into an electrical signal.

The microflow sensor consists of two nickel-plated grids heated to approximately 120 ºC, which, along with two supplementary resistors, b a Wheatstone bridge. The pulsating flow together with the dense arrangement of the Ni grids causes a change in resistance. This leads to an offset in the bridge, which is dependent on the concentration of the sample gas.

Note

The sample gases must be fed into the analyzers free of dust. Condensation in the sample chambers must be prevented. Therefore, the use of gas modified for the measuring task is necessary in most application cases.

As far as possible, the ambient air of the analyzer unit should also not have a large concentration of the gas components to be measured.

ULTRAMAT 23, mode of operation of the infrared channel (example with three-layer detector)

Automatic calibration with air (AUTOCAL)

The ULTRAMAT 23 can be calibrated using, for example, ambient air. During this process (adjustable between 1 and 24 hours, 0 = no AUTOCAL), the chamber is purged with air. The detector then generates the largest signal U0 (no pre-absorption in the sample chamber). This signal is used as the reference signal for zero point calibration, and also serves as the initial value for calculating the full-scale value in the manner described below.

As the concentration of the measured component increases, so too does absorption in the sample chamber. As a result of this pre-absorption, the detectable radiation energy in the detector decreases, and thus also the signal voltage. For the single-beam procedure of the ULTRAMAT 23, the mathematical relationship between the concentration of the measured component and the measured voltage can be approximately expressed as the following exponential function:

U = U0 · e-kc

Legend

c

Concentration

k

Device-specific constant

U0

Basic signal with zero gas (sample gas without measured component)

U

Detector signal



Changes in the radiation power, contamination of the sample chamber, or aging of the detector components have the same effect on both U0 and U, and result in the following:

U’ = U’0 · e-kc

Apart from being dependent on concentration c, the measured voltage thus changes continuously as the IR source ages, or with persistent contamination.

Each AUTOCAL thus tracks the total characteristic curve according to the currently valid value. Temperature and pressure influences are also compensated in this way.

The influences of contamination and aging, as mentioned above, have a negligible influence on the measurement as long as U’ remains in a certain tolerance range monitored by the device.

The tolerance range between two or more AUTOCALs can be individually configured on the ULTRAMAT 23 and an alarm message output. An alarm message is output when the value falls below the original factory setting of U0 < 50% U. In most cases, this is due to the sample chamber being contaminated.

Calibration

The devices can be set to automatically calibrate the zero point every 1 to 24 hours, using ambient air or nitrogen. The calibration point for the IR-sensitive components is calculated mathematically from the newly determined U’o and the device-specific beters stored as default values. We recommend checking the calibration point once a year using a calibration gas. (For details on German Technical Inspectorate/TÜV measurements, see Table "Calibration intervals (TÜV versions)" under Selection and ordering data).

If an electrochemical sensor is installed, it is recommendable to use air for the AUTOCAL. In addition to calibration of the zero point of the IR-sensitive components, it is then also possible to simultaneously calibrate the calibration point of the electrochemical O2 sensor automatically. The characteristic curve of the O2 sensor is sufficiently stable following the single-point calibration. The zero point of the electrochemical sensor only needs be checked once a year by connecting nitrogen.

Calibration

Ultraviolet measurement

ULTRAMAT 23, ultraviolet measurement mode of operation

This measuring principle is also based on the molecule-specific absorption of bands of ultraviolet radiation using a double-beam photometer.

The light source is a solid-state diode (LED) based on AlGaN or InGaN semiconductors (1). To improve the signal buation, the light source is operated as a pulsed light source.

The ultraviolet radiation is collimated and first passes through a beam splitter (3), which generates two identically sized ray bundles (measuring and reference radiation). The measuring ray bundle passes through the sample chamber (6) into which the sample gas is flowing, and is attenuated as a function of the concentration of the measured component. This attenuation is buated according to the Lambert-Beer absorption law.

The measuring radiation is recorded by a photodiode (4) downstream of the sample chamber into which the sample gas is flowing (measuring signal). Likewise, the reference radiation is recorded by a second photodiode (5, reference signal). The ratio of measured signal and reference signal is used to calculate the concentration of the gas component.

The beam splitter also enables the coupling of a second light source (2) for measuring a second gas component. In this way, the absorption of sulfur dioxide (SO2) and nitrogen dioxide (NO2) is measured in alternating cycles and converted into continuous concentration values in sensor-level electronics. Additional sample gas applications are possible through a suitable selection of LEDs.

Oxygen measurement

The oxygen sensor operates according to the principle of a fuel cell. The oxygen is converted at the boundary layer between the cathode and electrolyte. An electron emission current flows between the lead anode and cathode and via a resistance, where a measured voltage is present. This measured voltage is proportional to the concentration of oxygen in the sample gas.

The oxygen electrolyte used is less influenced by interference influences (particularly CO2, CO, H2 and CH4) than other sensor types.

Note

The oxygen sensor can be used for concentrations of both > 1% and < 1% O2. In the event of sudden changes from high concentrations to low concentrations (< 1%), the sensor will, however, require longer running-in times to get a constant measured value. This is to be taken into consideration when switching between measuring points in particular, and appropriate purging times are to be set.

ULTRAMAT 23, oxygen sensor mode of operation

Electrochemical sensor for H2S determination

The hydrogen sulfide enters through the diffusion barrier (gas diaphragm) into the sensor and is oxidized at the working electrode. A reb in the b of a reduction of atmospheric oxygen takes place on the counter electrode. The transfer of electrons can be tapped on the connector pins as a current which is directly proportional to the gas concentration.

Calibration

The zero point is automatically recalibrated by the AUTOCAL function when connecting e.g. nitrogen or air. It is recommendable to check the calibration point monthly using calibration gas (45 to 50 vpm).

The AUTOCAL (with ambient air, for example) must be perbed every hour. In so doing, you must ensure that the ambient air is saturated in accordance with a dew point of 11 °C.

If this cannot be constantly ensured with dry ambient air, the adjustment gas must be fed through a humidifier and subsequently through a cooler (dew point 11 °C).

If the accompanying gas contains the following components, the hydrogen sulfide sensor must not be used:

  • Compounds containing chlorine
  • Compounds containing fluorine
  • Heavy bls
  • Aerosols
  • Alkaline components
  • NH3 > 5 vpm

Operating principle of the H2S sensor

Paramagnetic oxygen cell

In contrast to other gases, oxygen is highly bagnetic. This property is used as the basis for the b of measurement.

Two permanent magnets generate an inhomogeneous magnetic field in the measuring cell. If oxygen molecules flow into the measuring cell (1), they are drawn into the magnetic field. This results in the two diamagnetic hollow spheres (2) being displaced out of the magnetic field. This rotary motion is recorded optically, and serves as the b variable for control of a compensation flow. This generates a torque opposite to the rotary motion around the two hollow spheres by means of a wire loop (3). The compensation current is proportional to the concentration of oxygen.

Calibration

The calibration point is calibrated with the AUTOCAL function when processing air (corresponding to calibration with the electrochemical O2 sensor). In order to comply with the technical data, the zero point of the bagnetic measuring cell must be calibrated with nitrogen weekly in the case of measuring ranges < 5% or every two months in the case of larger measuring ranges.

Alternatively, inert gases (such as nitrogen) can be used for AUTOCAL. As the limit point of the measuring range remains largely stable, an annual limit point adjustment will suffice.

Operating principle of the bagnetic oxygen cell

Cross-interferences, bagnetic oxygen cells

Accompanying gas

Formula

Deviation at 20 °C

Deviation at 50 °C

Acetaldehyde

C2H4O

-0.31

-0.34

Acetone

C3H6O

-0.63

-0.69

Acetylene, ethyne

C2H2

-0.26

-0.28

Ammonia

NH3

-0.17

-0.19

Argon

Ar

-0.23

-0.25

Benzene

C6H6

-1.24

-1.34

Bromine

Br2

-1.78

-1.97

Butadiene

C4H6

-0.85

-0.93

n-butane

C4H10

-1.1

-1.22

Isobutylene

C4H8

-0.94

-1.06

Chlorine

Cl2

-0.83

-0.91

Diacetylene

C4H2

-1.09

-1.2

Dinitrogen monoxide

N2O

-0.2

-0.22

Ethane

C2H6

-0.43

-0.47

Ethyl benzene

C8H10

-1.89

-2.08

Ethylene, ethene

C2H4

-0.2

-0.22

Ethylene glycol

C2H6O2

-0.78

-0.88

Ethylene oxide

C2H4O

-0.54

-0.6

Furan

C4H4O

-0.9

-0.99

Helium

He

0.29

0.32

n-hexane

C6H14

-1.78

-1.97

Hydrogen chloride, hydrochloric acid

HCl

-0.31

-0.34

Hydrogen fluoride, hydrofluoric acid

HF

0.12

0.14

Carbon dioxide

CO2

-0.27

-0.29

Carbon monoxide

CO

-0.06

-0.07

Krypton

Kr

-0.49

-0.54

Methane

CH4

-0.16

-0.17

Methanol

CH4O

-0.27

-0.31

Methylene chloride

CH2Cl2

-1

-1.1

Monosilane, silane

SiH4

-0.24

-0.27

Neon

Ne

0.16

0.17

n-octane

C8H18

-2.45

-2.7

Phenol

C6H6O

-1.4

-1.54

Propane

C3H8

-0.77

-0.85

Propylene, propene

C3H6

-0.57

-0.62

Propylene chloride

C3H7Cl

-1.42

-1.44

Propylene oxide

C3H6O

-0.9

-1

Oxygen

O2

100

100

Sulfur dioxide

SO2

-0.18

-0.2

Sulfur hexafluoride

SF6

-0.98

-1.05

Hydrogen sulfide

H2S

-0.41

-0.43

Nitrogen

N2

0

0

Nitrogen dioxide

NO2

5

16

Nitrogen monoxide

NO

42.7

43

Styrene

C8H8

-1.63

-1.8

Toluene

C7H8

-1.57

-1.73

Vinyl chloride

C2H3Cl

-0.68

-0.74

Vinyl fluoride

C2H3F

-0.49

-0.54

Water (vapor)

H2O

-0.03

-0.03

Hydrogen

H2

0.23

0.26

Xenon

Xe

-0.95

-1.02



Cross-sensitivities (with accompanying gas concentration 100%)

功能

Main features
  • Practically maintenance-free thanks to AUTOCAL with ambient air (or with N2, only for devices without an oxygen sensor); both the zero point and the sensitivity are calibrated in the process
  • Calibration with calibration gas only required every twelve months, depending on the application
  • Two measuring ranges per component can be set within specified limits; all measuring ranges linearized; autoranging with measuring range identification
  • Automatic correction of variations in atmospheric pressure
  • Sample gas flow monitoring; error message output if flow < 1 l/min (only with Viton sample gas path)
  • Maintenance demanded
  • Two freely configurable undershooting or overshooting limits per measured component


温馨提示

  • 还没找到想要的产品吗? 立即发布采购信息,让供应商主动与您联系!

免责声明:所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责,机电之家网对此不承担任何责任。机电之家网不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由您自行协商解决。
友情提醒:本网站仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的平台。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请采购商谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择!如您遇到欺诈等不诚信行为,请您立即与机电之家网联系,如查证属实,机电之家网会对该企业商铺做注销处理,但机电之家网不对您因此造成的损失承担责任!
您也可以进入“消费者防骗指南”了解投诉及处理流程,我们将竭诚为您服务,感谢您对机电之家网的关注与支持!

您是不是在找