6ES7400-0HR02-4AB0

6ES7400-0HR02-4AB0
SIMATIC S7-400H,414-5H H 系统捆绑版本,带 1 x UR2-H,不带存储卡 2 x PS407 UC120/230V,10A, 4 X 同步模块,高达 10m, 2 X 同步电缆 1m, 2 x CPU 414-5H, 4 X 备用电池
联系人:郭金秀
24小时销售及维修热线:15216632215
手 机:15216632215 Q Q : 498588739
邮箱:498588739@qq.com

SIMATIC S7-400H,414-5H H 系统捆绑版本,带 1 x UR2-H,不带存储卡 2 x PS407 UC120/230V,10A, 4 X 同步模块,高达 10m, 2 X 同步电缆 1m, 2 x CPU 414-5H, 4 X 备用电池
SIMATIC S7-400H,414-5H H 系统捆绑版本,带 1 x UR2-H,不带存储卡 2 x PS 405 10A,DC 24/48/60V, 4 X 同步模块,高达 10m, 2 X 同步电缆 1m, 2 x CPU 414-5H, 4 X 备用电池
SIMATIC S7-400H,CPU 414-5H, 中央组件,用于 S7-400H 和 S7-400F, 5 个接口: 1x MPI/DP,1x DP,1x PN 和 2 个同步模块接口, 4 MB 存储器 (2 MB 数据/2 MB 程序)

概述

  • 用于 SIMATIC S7-400H 和 S7-400F/FH。
  • 可应用在高可用性的 S7-400H 系统中
  • 可与故障安全 S7-400F/FH 系统中 F 运行授权与 F 兼容 CPU 一起使用。
  • 带有内置的 PROFIBUS DP 主站接口
  • 带两个用于 Sync 模块的插槽

应用

CPU 414–5H 是用于 SIMATIC S7-400H 和 S7-400 F/FH 的 CPU。它允许配置为一个容错的 S7-400H 系统。它可与 F 运行授权一起用于故障安全 S7-400®F/FH 自动化系统。内置的PROFIBUS-DP接口使它能够作为主站或从站直接连接到PROFIBUS-DP现场总线。

设计

CPU 414-5H 拥有:

  • 功能强大的处理器: 
    CPU 处理每条二进制指令的时间小于 18.75 ns。
  • 4 MB 主存储器(2 MB 用于程序,2 MB 用于数据);
    装载存储器用于存放 S7-400H F/FH 自动化系统的用户程序和组态数据;高速主存储器用于存放与过程相关的用户程序的子程序
  • 存储卡: 
    用于扩展内置装载存储器。 除程序本身之外,装载存储器中所含的信息还包括 S7-400H F/FH 的组态数据,这就是要在存储器中占据双倍空间的原因。 其结果是:
    • 内置的装载存储器不能满足大程序量的要求,因此需要存储卡。 
      提供有 RAM 和 FEPROM 卡(FEPROM 用于在断开电源时保存数据)。
  • 灵活的扩展选件: 
    多达 131,072 点数字量和 81,932 点模拟量输入/输出。
  • MPI 多点接口: 
    MPI 可用来建立一个 32 个节点的简单网络,数据传输速率 187.5 Kbit/s。CPU 可以与通信总线(C 总线)上的节点和 MPI 上的节点建立最多 64 个连接。 
    注:
    当同时使用 PROFIBUS DP 和 MPI 接口时,只能将下列总线连接器连接到 MPI 接口:
    • 带插口: 6ES7 972-0BB42-0XA0
    • 不带插口: 6ES7 972-0BA42-0XA0
  • PROFIBUS DP 接口: 
    通过 PROFIBUS DP 接口,可以实现冗余、分布式自动化组态,从而提高了速度,便于使用。对用户来说,分布式 I/O 作为集中式 I/O 来处理(相同的组态、编址和编程)。
  • PROFINET 接口,带 2 个端口(交换机): 
    支持系统冗余和 MRP(介质冗余协议)
  • 模式选择开关: 
    拨动开关设计。
  • 诊断缓冲区: 
    最后的 120 个报警和中断事件保存在一个环形缓冲区中,用于进行诊断。
  • 实时时钟: 
    CPU 提供带日期和时间的诊断报告。
  • PROFIBUS DP 接口: 
    通过带 PROFIBUS DP 主站接口的 CPU 414-5H,可迅速建立起操作方便的分布式自动化系统。对用户来说,分布式 I/O 作为集中式 I/O 来处理(相同的组态、编址和编程)。 
    注:
    当同时使用 PROFIBUS DP 和 MPI 接口时,只能将下列总线连接器连接到 MPI 接口:
    • 带插口: 6ES7 972-0BB42-0XA0
    • 不带插口: 6ES7 972-0BA42-0XA0

功能

  • Block protection: 
    A password concept also protects the user program from unauthorized access as well as the keyswitch.
  • Integrated HMI services: 
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communication functions:
    • PG/OP communication
    • Expanded communication (simple and high-availability)
Configurable Attributes

The STEP 7 "hardware configuration" tool and the installed S7-400H options package are used to configure the features and response of the S7-400H, including the CPUs, for example:

  • Multipoint interface MPI:
    • Definition of node addresses
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communication load
  • Address alb: 
    Addressing of I/O modules
  • Retentive area: 
    Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
  • Protection level: 
    Definition of access authorizations to program and data
  • System diagnostics: 
    Definition of the handling and scope of diagnostics messages
  • Timed interrupts: 
    Setting of periods
  • Configuration of H stations
Safety-related functions

The F-runtime license can be used to compile the failsafe F user program and run it on the CPU. A license is required for each S7-400F/FH system. 2 TÜV stickers are included.

Reporting functions
  • Status and fault indicators: 
    LEDs indicate internal and external errors and operating modes such as RUN, STOP, Startup, "Master” mode, redundancy error, test function, etc.
  • Test functions: 
    The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
  • Inbation functions: 
    The PG can be used to provide the user with inbation about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.